FRED™ Jr. System — official Smith+Nephew representative image
Flow diverter · Flow Diversion & Stents

FRED™ Jr. SystemProduct Code (REF): FREDJR2508

The FRED Jr. System is a dual-layer flow re-direction endoluminal device sized for smaller intracranial vessels and more distal aneurysm locations than the standard FRED platform, redirecting flow away from the aneurysm sac while preserving flow into covered branch vessels.

This page documents catalog code (REF) FREDJR2508, one of 8 available configurations of the FRED™ Jr. System. See the full FRED™ Jr. System overview for every configuration.

Available under product codes FREDJR2508, FREDJR2513, FREDJR2520, FREDJR2526, FREDJR3009, FREDJR3014, FREDJR3021, FREDJR3027.

Sizes & Specifications

Fully open implant diameter
2.5 mm – 3.0 mm
Working / total length
8 mm – 41 mm
Delivery microcatheter
Headway 21

Manufacturer: Terumo Neuro (MicroVention, Inc.) · Reference source: terumoneuro.com

Design & Technology

Technical characteristics and diagrams as published by Terumo Neuro (MicroVention).

The FRED™ and FRED™ Jr. flow diversion devices feature a unique dual layer construction designed to achieve excellent vessel wall apposition, which fosters neointimal growth and long-term aneurysm occlusion. The FRED™ Jr. is optimized for distal locations. Both devices may be used with or without embolic coils.

FRED™ Jr. System — official product image (Terumo Neuro)

Immediate Opening

Innovative and elegant device design results in easy device sizing, deployment, and device opening

Precise, Predictable Placement

Consistent device opening and ability to recapture and reposition for precise placement

Effective

Dual action design provides vessel wall stability and conformance for effective flow diversion

Product Identification & Specifications

Reference identifiers for procurement, registration and tender documentation.

Product CodeFREDJR2508
REF NumbersFREDJR2508, FREDJR2513, FREDJR2520, FREDJR2526, FREDJR3009, FREDJR3014, FREDJR3021, FREDJR3027
ManufacturerTerumo Neuro (MicroVention, Inc.)
BrandTerumo Neuro (MicroVention)
Product FamilyFlow Diversion & Stents
Country AvailabilityAzerbaijan

Clinical Applications

The FRED™ Jr. System is a flow diverter in the Flow Diversion & Stents family from Terumo Neuro (MicroVention, Inc.), used by interventional specialists in procedures where a flow diverter of this class is indicated. It is supplied in 8 configurations (catalog codes FREDJR2508 through FREDJR3027) to match anatomical and procedural requirements.

For the complete indications for use, contraindications and instructions for use (IFU), request the official Terumo Neuro (MicroVention) documentation through our clinical team. Azmed Devices supplies the FRED™ Jr. System to hospitals and clinics across Azerbaijan.

Ordering Information

Catalog reference codes as published by Terumo Neuro (MicroVention). Contact us to confirm current availability.

Catalog #FREDJR2508
Fully Open Implant Diameter (mm)2.5
Working Length / Total Length by Target Vessel (mm)2.0mm: 11/15 · 2.5mm: 8/13
Catalog #FREDJR2513
Fully Open Implant Diameter (mm)2.5
Working Length / Total Length by Target Vessel (mm)2.0mm: 17/21 · 2.5mm: 13/18
Catalog #FREDJR2520
Fully Open Implant Diameter (mm)2.5
Working Length / Total Length by Target Vessel (mm)2.0mm: 28/32 · 2.5mm: 20/25
Catalog #FREDJR2526
Fully Open Implant Diameter (mm)2.5
Working Length / Total Length by Target Vessel (mm)2.0mm: 35/38 · 2.5mm: 26/30
Catalog #FREDJR3009
Fully Open Implant Diameter (mm)3.0
Working Length / Total Length by Target Vessel (mm)2.5mm: 12/16 · 3.0mm: 9/13
Catalog #FREDJR3014
Fully Open Implant Diameter (mm)3.0
Working Length / Total Length by Target Vessel (mm)2.5mm: 19/23 · 3.0mm: 14/19
Catalog #FREDJR3021
Fully Open Implant Diameter (mm)3.0
Working Length / Total Length by Target Vessel (mm)2.5mm: 29/34 · 3.0mm: 21/27
Catalog #FREDJR3027
Fully Open Implant Diameter (mm)3.0
Working Length / Total Length by Target Vessel (mm)2.5mm: 37/41 · 3.0mm: 27/32

Downloads & Documentation

Instructions for use (IFU), technical datasheets and clinical literature for the FRED™ Jr. System are available on request from our clinical team.

Request Documentation

Frequently Asked Questions

What does this product page list?
This product page lists the material codes and material descriptions from the supplied source image.
Does the catalog add clinical or compatibility claims?
No. It is limited to the material codes and material descriptions printed in the source image; clinical, compatibility and availability details must be confirmed in the applicable manufacturer documentation.
How can we request documentation for a listed code?
Contact Azmed Devices with the material code from the ordering table. We can coordinate a documentation or availability request without changing the source description.

Related in Flow Diversion & Stents