SELUTION SLR PTCA Drug Eluting Balloon — official Smith+Nephew representative image
PTCA coronary drug eluting balloon · Coronary Interventions

SELUTION SLR PTCA Drug Eluting BalloonProduct Code (REF): SC14-400025

The SELUTION SLR PTCA Drug Eluting Balloon represents a shift in coronary intervention technology, intended to go beyond traditional metal implants. Its design philosophy centers on providing a consistent and predictable drug release profile that is intended to be comparable to the latest generation of drug-eluting stents. By utilizing a proprietary phospholipid coating and microreservoir technology, the device is designed to facilitate improved drug uptake and retention within the tissue while minimizing drug loss during the procedural phase. The system is designed to provide sustained limus release for up to 90 days, offering a localized anti-inflammatory effect without the need for a permanent metallic scaffold. This approach supports a hybrid strategy, allowing practitioners to minimize the amount of implanted metal in the vessel. The broader size matrix is designed to extend clinical treatment options for various manifestations of coronary artery disease, supporting complex procedures such as the treatment of long, calcified, or bifurcation lesions. Cordis presents SELUTION SLR as a new paradigm for coronary interventions: breakthrough technology to deliver sustained limus release for up to 90 days. According to Cordis, SELUTION SLR DEB was the first drug-eluting balloon to be awarded Breakthrough Device designation by the US Food and Drug Administration (FDA). The device is also being evaluated in the SELUTION DeNovo Study — a prospective, randomized, multi-center, international, single-blind clinical trial comparing a SELUTION SLR DEB strategy versus a drug-eluting stent (DES) strategy in 3,326 patients with 1:1 randomization. Cordis describes it as a landmark randomized trial for coronary de-novo lesions with all-comers enrollment, designed to evaluate non-inferiority at 1 year and possible superiority at 5 years, with target vessel failure at 1 and 5 years as the primary endpoints.

This page documents catalog code (REF) SC14-400025, one of 84 available configurations of the SELUTION SLR PTCA Drug Eluting Balloon. See the full SELUTION SLR PTCA Drug Eluting Balloon overview for every configuration.

Available under product codes SC14-150010, SC14-150015, SC14-150020, SC14-150025, SC14-150030, SC14-150035, SC14-150040, SC14-200010 and 76 more (see Ordering Information below).

Sizes & Specifications

Balloon diameters
1.50 – 5.00 mm (12 diameters)
Balloon lengths
10, 15, 20, 25, 30, 35, 40 mm
Guide catheter compatibility
≥ 5 Fr for 1.50 – 3.75 mm balloons; ≥ 6 Fr for 4.00 – 5.00 mm balloons

Manufacturer: Cordis · Reference source: cordis.com

Design & Technology

Technical characteristics and diagrams as published by Cordis.

The SELUTION DeNovo Study

A prospective, randomized, multi-center, international, single-blind clinical trial comparing the SELUTION SLR DEB strategy versus a drug-eluting stent (DES) strategy, as described by Cordis. 3,326 patients are randomized 1:1 between the DEB arm (with vessel preparation) and a DES arm per standard of care.

Study design, as published by Cordis
  1. 1.Landmark randomized trial for coronary de-novo lesions, all-comers enrollment.
  2. 2.Designed to evaluate non-inferiority at 1 year and possible superiority at 5 years.
  3. 3.Primary endpoints: target vessel failure at 1 year and 5 years.
SELUTION DeNovo Study randomization diagram: 3,326 patients randomized 1:1 between the DEB arm with vessel preparation and a DES arm per standard of care

Diagram and study description as published by Cordis (SELUTION SLR PTCA product page, cordis.com). Currently enrolling; refer to Cordis for study status and citations.

Product Features

Design characteristics as published by Cordis.

Microscopic view of the SELUTION SLR proprietary phospholipid coating

Proprietary Phospholipid Coating

Facilitates drug uptake and retention in the tissue while minimizing drug loss during the procedure.

SELUTION SLR MicroReservoirs sphere render

MicroReservoir Technology

Achieves consistent and predictable drug release at therapeutic levels comparable to drug-eluting stents.

Sustained Limus Release

Delivers sustained limus release to the vessel wall for up to 90 days.

SELUTION SLR size matrix spiral graphic

Broad Size Matrix

Offers an extensive range of sizes to extend treatment options for coronary artery disease.

FDA Breakthrough Device Designation

According to Cordis, SELUTION SLR DEB was the first drug-eluting balloon to be awarded Breakthrough Device designation by the US FDA.

SELUTION DeNovo Study

A prospective, randomized, multi-center, international, single-blind trial (N = 3,326, 1:1 randomization) comparing a SELUTION SLR DEB strategy versus a drug-eluting stent strategy for coronary de-novo lesions, with target vessel failure at 1 and 5 years as primary endpoints.

Documentation

Official IFU, sizing charts and full specifications are available on request through Azmed Devices.

Product Identification & Specifications

Reference identifiers for procurement, registration and tender documentation.

Product CodeSC14-400025
REF NumbersSC14-150010, SC14-150015, SC14-150020, SC14-150025, SC14-150030, SC14-150035, SC14-150040, SC14-200010, SC14-200015, SC14-200020, SC14-200025, SC14-200030, SC14-200035, SC14-200040, SC14-225010, SC14-225015, SC14-225020, SC14-225025, SC14-225030, SC14-225035, SC14-225040, SC14-250010, SC14-250015, SC14-250020, SC14-250025, SC14-250030, SC14-250035, SC14-250040, SC14-275010, SC14-275015, SC14-275020, SC14-275025, SC14-275030, SC14-275035, SC14-275040, SC14-300010, SC14-300015, SC14-300020, SC14-300025, SC14-300030, SC14-300035, SC14-300040, SC14-325010, SC14-325015, SC14-325020, SC14-325025, SC14-325030, SC14-325035, SC14-325040, SC14-350010, SC14-350015, SC14-350020, SC14-350025, SC14-350030, SC14-350035, SC14-350040, SC14-375010, SC14-375015, SC14-375020, SC14-375025, SC14-375030, SC14-375035, SC14-375040, SC14-400010, SC14-400015, SC14-400020, SC14-400025, SC14-400030, SC14-400035, SC14-400040, SC14-450010, SC14-450015, SC14-450020, SC14-450025, SC14-450030, SC14-450035, SC14-450040, SC14-500010, SC14-500015, SC14-500020, SC14-500025, SC14-500030, SC14-500035, SC14-500040
ManufacturerCordis
BrandCordis
Product FamilyCoronary Interventions
Country AvailabilityAzerbaijan

Clinical Applications

The SELUTION SLR PTCA Drug Eluting Balloon is a ptca coronary drug eluting balloon in the Coronary Interventions family from Cordis, used by interventional specialists in procedures where a ptca coronary drug eluting balloon of this class is indicated. It is supplied in 84 configurations (catalog codes SC14-150010 through SC14-500040) to match anatomical and procedural requirements.

For the complete indications for use, contraindications and instructions for use (IFU), request the official Cordis documentation through our clinical team. Azmed Devices supplies the SELUTION SLR PTCA Drug Eluting Balloon to hospitals and clinics across Azerbaijan.

Ordering Information

Catalog reference codes as published by Cordis. Contact us to confirm current availability.

Showing 84 of 84 configurations

Balloon diameter (mm)1.50
Balloon length (mm)10
Balloon diameter (mm)1.50
Balloon length (mm)15
Balloon diameter (mm)1.50
Balloon length (mm)20
Balloon diameter (mm)1.50
Balloon length (mm)25
Balloon diameter (mm)1.50
Balloon length (mm)30
Balloon diameter (mm)1.50
Balloon length (mm)35
Balloon diameter (mm)1.50
Balloon length (mm)40
Balloon diameter (mm)2.00
Balloon length (mm)10
Balloon diameter (mm)2.00
Balloon length (mm)15
Balloon diameter (mm)2.00
Balloon length (mm)20
Balloon diameter (mm)2.00
Balloon length (mm)25
Balloon diameter (mm)2.00
Balloon length (mm)30
Balloon diameter (mm)2.00
Balloon length (mm)35
Balloon diameter (mm)2.00
Balloon length (mm)40
Balloon diameter (mm)2.25
Balloon length (mm)10
Balloon diameter (mm)2.25
Balloon length (mm)15
Balloon diameter (mm)2.25
Balloon length (mm)20
Balloon diameter (mm)2.25
Balloon length (mm)25
Balloon diameter (mm)2.25
Balloon length (mm)30
Balloon diameter (mm)2.25
Balloon length (mm)35
Balloon diameter (mm)2.25
Balloon length (mm)40
Balloon diameter (mm)2.50
Balloon length (mm)10
Balloon diameter (mm)2.50
Balloon length (mm)15
Balloon diameter (mm)2.50
Balloon length (mm)20
Balloon diameter (mm)2.50
Balloon length (mm)25
Balloon diameter (mm)2.50
Balloon length (mm)30
Balloon diameter (mm)2.50
Balloon length (mm)35
Balloon diameter (mm)2.50
Balloon length (mm)40
Balloon diameter (mm)2.75
Balloon length (mm)10
Balloon diameter (mm)2.75
Balloon length (mm)15
Balloon diameter (mm)2.75
Balloon length (mm)20
Balloon diameter (mm)2.75
Balloon length (mm)25
Balloon diameter (mm)2.75
Balloon length (mm)30
Balloon diameter (mm)2.75
Balloon length (mm)35
Balloon diameter (mm)2.75
Balloon length (mm)40
Balloon diameter (mm)3.00
Balloon length (mm)10
Balloon diameter (mm)3.00
Balloon length (mm)15
Balloon diameter (mm)3.00
Balloon length (mm)20
Balloon diameter (mm)3.00
Balloon length (mm)25
Balloon diameter (mm)3.00
Balloon length (mm)30
Balloon diameter (mm)3.00
Balloon length (mm)35
Balloon diameter (mm)3.00
Balloon length (mm)40
Balloon diameter (mm)3.25
Balloon length (mm)10
Balloon diameter (mm)3.25
Balloon length (mm)15
Balloon diameter (mm)3.25
Balloon length (mm)20
Balloon diameter (mm)3.25
Balloon length (mm)25
Balloon diameter (mm)3.25
Balloon length (mm)30
Balloon diameter (mm)3.25
Balloon length (mm)35
Balloon diameter (mm)3.25
Balloon length (mm)40
Balloon diameter (mm)3.50
Balloon length (mm)10
Balloon diameter (mm)3.50
Balloon length (mm)15
Balloon diameter (mm)3.50
Balloon length (mm)20
Balloon diameter (mm)3.50
Balloon length (mm)25
Balloon diameter (mm)3.50
Balloon length (mm)30
Balloon diameter (mm)3.50
Balloon length (mm)35
Balloon diameter (mm)3.50
Balloon length (mm)40
Balloon diameter (mm)3.75
Balloon length (mm)10
Balloon diameter (mm)3.75
Balloon length (mm)15
Balloon diameter (mm)3.75
Balloon length (mm)20
Balloon diameter (mm)3.75
Balloon length (mm)25
Balloon diameter (mm)3.75
Balloon length (mm)30
Balloon diameter (mm)3.75
Balloon length (mm)35
Balloon diameter (mm)3.75
Balloon length (mm)40
Balloon diameter (mm)4.00
Balloon length (mm)10
Balloon diameter (mm)4.00
Balloon length (mm)15
Balloon diameter (mm)4.00
Balloon length (mm)20
Balloon diameter (mm)4.00
Balloon length (mm)25
Balloon diameter (mm)4.00
Balloon length (mm)30
Balloon diameter (mm)4.00
Balloon length (mm)35
Balloon diameter (mm)4.00
Balloon length (mm)40
Balloon diameter (mm)4.50
Balloon length (mm)10
Balloon diameter (mm)4.50
Balloon length (mm)15
Balloon diameter (mm)4.50
Balloon length (mm)20
Balloon diameter (mm)4.50
Balloon length (mm)25
Balloon diameter (mm)4.50
Balloon length (mm)30
Balloon diameter (mm)4.50
Balloon length (mm)35
Balloon diameter (mm)4.50
Balloon length (mm)40
Balloon diameter (mm)5.00
Balloon length (mm)10
Balloon diameter (mm)5.00
Balloon length (mm)15
Balloon diameter (mm)5.00
Balloon length (mm)20
Balloon diameter (mm)5.00
Balloon length (mm)25
Balloon diameter (mm)5.00
Balloon length (mm)30
Balloon diameter (mm)5.00
Balloon length (mm)35
Balloon diameter (mm)5.00
Balloon length (mm)40

Size matrix and REF codes from the official Cordis SELUTION SLR brochure (100640237, 05.2024). Guide catheter compatibility: ≥ 5 Fr for 1.50 – 3.75 mm balloon diameters, ≥ 6 Fr for 4.00 – 5.00 mm.

Downloads & Documentation

Instructions for use (IFU), technical datasheets and clinical literature for the SELUTION SLR PTCA Drug Eluting Balloon are available on request from our clinical team.

Request Documentation

Frequently Asked Questions

How long does the SELUTION SLR provide drug release?
It is designed to deliver sustained limus release for up to 90 days.
What is the benefit of the phospholipid coating?
The coating facilitates drug uptake and retention in the tissue while minimizing drug loss during the procedure.
What is the SELUTION DeNovo Study?
According to Cordis, it is a prospective, randomized, multi-center, international, single-blind clinical trial comparing the SELUTION SLR DEB strategy versus a drug-eluting stent (DES) strategy in 3,326 patients, designed to evaluate non-inferiority at 1 year and possible superiority at 5 years, with target vessel failure at 1 and 5 years as the primary endpoints.
Does SELUTION SLR have any special regulatory designations?
Cordis reports that SELUTION SLR DEB was the first drug-eluting balloon to be awarded Breakthrough Device designation by the US Food and Drug Administration (FDA).
How can our hospital order SELUTION SLR PTCA Drug Eluting Balloon in Azerbaijan?
Contact Azmed Devices at info@azmeddevices.com. We provide manufacturer documentation, registration status and tender support, and coordinate supply directly with Cordis.

Related in Coronary Interventions