LVIS™ & LVIS™ Jr
Intracranial stent · Поток-перенаправляющие устройства и стенты

LVIS™ & LVIS™ JrКод изделия (REF): 172530-CASJ

LVIS™ (Low-profile Visualized Intraluminal Support) and LVIS™ Jr are braided, closed-cell intracranial stents designed to assist coil embolization of wide-neck aneurysms. The stent is placed in the parent artery spanning the aneurysm neck, preventing coil loops from herniating into the parent vessel during packing and allowing higher coil fill densities than are achievable with balloon assist alone. The braided construction provides full-length radiopacity — every strut is visualized under fluoroscopy — enabling precise deployment and accurate post-deployment assessment. Beyond mechanical coil containment, the LVIS platform's higher metallic surface area also contributes a mild flow diversion effect, further promoting progressive thrombosis of the aneurysm sac over time. This dual mechanism of coil support plus flow modification makes LVIS particularly useful in fusiform or partially thrombosed aneurysms where pure coil embolization is insufficient. LVIS is delivered through a Headway 17 or 21 microcatheter; LVIS Jr is designed for vessels down to 2.0 mm where the standard LVIS would oversize. LVIS is available in nominal diameters from 3.5 mm to 5.5 mm with working lengths from 12 mm to 32 mm. LVIS Jr covers 2.5 mm to 3.5 mm diameters with working lengths from 13 mm to 33 mm.

Эта страница содержит сведения о каталожном коде (REF) 172530-CASJ, одной из 20 доступных конфигураций LVIS™ & LVIS™ Jr. См. полный обзор LVIS™ & LVIS™ Jr по каждой конфигурации.

Доступно под кодом(-ами) изделия 212517-CAS, 212525-CAS, 212912-CAS, 212917-CAS, 212922-CAS, 212928-CAS, 212931-CAS, 213015-CAS и ещё 12 (см. раздел «Информация для заказа» ниже).

Размеры и технические характеристики

Diameter
2.5 mm – 5.5 mm
Length
15 mm – 32 mm
Delivery microcatheter
Headway 17 / 21

Производитель: Terumo Neuro (MicroVention, Inc.) · Источник данных: terumoneuro.com

Конструкция и технология

Технические характеристики и схемы согласно публикациям Terumo Neuro (MicroVention).

LVIS™ and LVIS™ Jr. devices are braided coil assist stents used for aneurysm embolization.

LVIS™ & LVIS™ Jr — official product image (Terumo Neuro)

Control & Visibility

The braided construction allows physicians to control the stent deployment to achieve optimal placement. Radiopaque strands along the entire stent body allow physicians to visualize the stent expansion.

Conformance to Vessel Wall

The braided design allows individual wires to slide during deployment, allowing the stent to conform to the shape of the vessel, even in tortuous anatomies

Coil Mass Support

The high metal coverage and small pore size provide consistent support of coil mass including small finishing coils

Идентификация и технические характеристики изделия

Референсные идентификаторы для закупок, регистрации и тендерной документации.

Код изделия172530-CASJ
Номер(а) REF212517-CAS, 212525-CAS, 212912-CAS, 212917-CAS, 212922-CAS, 212928-CAS, 212931-CAS, 213015-CAS, 213025-CAS, 213041-CAS, 214035-CAS, 214049-CAS, 172010-CASJ, 172014-CASJ, 172020-CASJ, 172032-CASJ, 172516-CASJ, 172524-CASJ, 172530-CASJ, 172537-CASJ
ПроизводительTerumo Neuro (MicroVention, Inc.)
БрендTerumo Neuro (MicroVention)
Семейство продукцииПоток-перенаправляющие устройства и стенты
Доступность по странамАзербайджан

Клиническое применение

LVIS™ & LVIS™ Jr — это intracranial stent в семействе Поток-перенаправляющие устройства и стенты от Terumo Neuro (MicroVention, Inc.), применяемый специалистами по интервенционным вмешательствам в процедурах, где показано использование intracranial stent данного класса. Поставляется в 20 конфигурациях (каталожные коды с 212517-CAS по 172537-CASJ) для соответствия анатомическим и процедурным требованиям.

Для получения полного перечня показаний к применению, противопоказаний и инструкции по применению (IFU) запросите официальную документацию Terumo Neuro (MicroVention) через нашу клиническую команду. Azmed Devices поставляет LVIS™ & LVIS™ Jr больницам и клиникам по всему Азербайджану.

Информация для заказа

Каталожные референсные коды согласно публикациям Terumo Neuro (MicroVention). Свяжитесь с нами для подтверждения текущей доступности.

Catalog #212517-CAS
Product LineLVIS
Diameter × Total Length (mm)3.5 x 17
Working Length / Total Length by Target Vessel (mm)2.5mm: 23/19 · 3.0mm: 20/16 · 3.5mm: 17/13
Catalog #212525-CAS
Product LineLVIS
Diameter × Total Length (mm)3.5 x 22
Working Length / Total Length by Target Vessel (mm)2.5mm: 32/28 · 3.0mm: 27/23 · 3.5mm: 22/18
Catalog #212912-CAS
Product LineLVIS
Diameter × Total Length (mm)4.0 x 12
Working Length / Total Length by Target Vessel (mm)2.5mm: 16/12 · 3.0mm: 15/11 · 3.5mm: 14/10 · 4.0mm: 12/8
Catalog #212917-CAS
Product LineLVIS
Diameter × Total Length (mm)4.0 x 17
Working Length / Total Length by Target Vessel (mm)2.5mm: 27/23 · 3.0mm: 24/20 · 3.5mm: 21/17 · 4.0mm: 17/13
Catalog #212922-CAS
Product LineLVIS
Diameter × Total Length (mm)4.0 x 22
Working Length / Total Length by Target Vessel (mm)2.5mm: 37/33 · 3.0mm: 34/30 · 3.5mm: 29/25 · 4.0mm: 22/18
Catalog #212928-CAS
Product LineLVIS
Diameter × Total Length (mm)4.0 x 28
Working Length / Total Length by Target Vessel (mm)2.5mm: 48/44 · 3.0mm: 43/39 · 3.5mm: 37/33 · 4.0mm: 28/24
Catalog #212931-CAS
Product LineLVIS
Diameter × Total Length (mm)4.0 x 31
Working Length / Total Length by Target Vessel (mm)2.5mm: 54/50 · 3.0mm: 48/44 · 3.5mm: 41/37 · 4.0mm: 31/27
Catalog #213015-CAS
Product LineLVIS
Diameter × Total Length (mm)4.5 x 18
Working Length / Total Length by Target Vessel (mm)3.0mm: 28/24 · 3.5mm: 26/22 · 4.0mm: 22/18 · 4.5mm: 18/14
Catalog #213025-CAS
Product LineLVIS
Diameter × Total Length (mm)4.5 x 23
Working Length / Total Length by Target Vessel (mm)3.0mm: 40/36 · 3.5mm: 36/32 · 4.0mm: 31/27 · 4.5mm: 23/19
Catalog #213041-CAS
Product LineLVIS
Diameter × Total Length (mm)4.5 x 32
Working Length / Total Length by Target Vessel (mm)3.0mm: 57/53 · 3.5mm: 52/48 · 4.0mm: 44/40 · 4.5mm: 32/28
Catalog #214035-CAS
Product LineLVIS
Diameter × Total Length (mm)5.5 x 30
Working Length / Total Length by Target Vessel (mm)4.0mm: 51/47 · 4.5mm: 45/41 · 5.0mm: 39/35 · 5.5mm: 30/26
Catalog #214049-CAS
Product LineLVIS
Diameter × Total Length (mm)5.5 x 33
Working Length / Total Length by Target Vessel (mm)4.0mm: 58/54 · 4.5mm: 51/47 · 5.0mm: 43/39 · 5.5mm: 33/29
Catalog #172010-CASJ
Product LineLVIS Jr
Diameter × Total Length (mm)2.5 x 13
Working Length / Total Length by Target Vessel (mm)2.0mm: 14/10 · 2.5mm: 13/9
Catalog #172014-CASJ
Product LineLVIS Jr
Diameter × Total Length (mm)2.5 x 17
Working Length / Total Length by Target Vessel (mm)2.0mm: 18/14 · 2.5mm: 17/13
Catalog #172020-CASJ
Product LineLVIS Jr
Diameter × Total Length (mm)2.5 x 23
Working Length / Total Length by Target Vessel (mm)2.0mm: 24/20 · 2.5mm: 23/19
Catalog #172032-CASJ
Product LineLVIS Jr
Diameter × Total Length (mm)2.5 x 34
Working Length / Total Length by Target Vessel (mm)2.0mm: 36/32 · 2.5mm: 34/30
Catalog #172516-CASJ
Product LineLVIS Jr
Diameter × Total Length (mm)3.5 x 18
Working Length / Total Length by Target Vessel (mm)2.5mm: 20/16 · 3.0mm: 19/15 · 3.5mm: 18/14
Catalog #172524-CASJ
Product LineLVIS Jr
Diameter × Total Length (mm)3.5 x 23
Working Length / Total Length by Target Vessel (mm)2.5mm: 27/23 · 3.0mm: 25/21 · 3.5mm: 23/19
Catalog #172530-CASJ
Product LineLVIS Jr
Diameter × Total Length (mm)3.5 x 28
Working Length / Total Length by Target Vessel (mm)2.5mm: 34/30 · 3.0mm: 32/28 · 3.5mm: 28/24
Catalog #172537-CASJ
Product LineLVIS Jr
Diameter × Total Length (mm)3.5 x 33
Working Length / Total Length by Target Vessel (mm)2.5mm: 40/36 · 3.0mm: 37/33 · 3.5mm: 33/29

Загрузки и документация

Инструкция по применению (IFU), технические спецификации и клиническая литература для LVIS™ & LVIS™ Jr доступны по запросу у нашей клинической команды.

Запросить документацию

Часто задаваемые вопросы

What is LVIS™ and what is it used for?
LVIS™ (Low-profile Visualized Intraluminal Support) is a braided, fully radiopaque intracranial stent used to assist coil embolization of wide-neck aneurysms. It scaffolds the aneurysm neck from the parent artery, preventing coil loops from herniating into the vessel during packing and enabling higher final coil fill densities. Its high metallic surface area also contributes a mild flow diversion effect that supplements progressive aneurysm thrombosis.
What is the difference between LVIS™ and LVIS™ Jr?
LVIS covers nominal diameters 3.5–5.5 mm for standard-calibre intracranial vessels, delivered via Headway 17 or 21. LVIS Jr covers 2.5–3.5 mm nominal diameters for smaller intracranial vessels (parent artery ≥2.0 mm), also delivered via Headway 17 or 21. LVIS Jr uses the same braided closed-cell construction and full-length radiopacity as standard LVIS.
What catalog numbers does LVIS™ come in?
LVIS standard: 212517-CAS through 214049-CAS (3.5–5.5 mm × 12–32 mm working length). LVIS Jr: 172010-CASJ through 172537-CASJ (2.5–3.5 mm × 13–33 mm working length). Both lines are delivered via Headway 17 (for smaller sizes) or Headway 21.
Does LVIS™ require antiplatelet therapy?
Yes. As an intracranial stent, LVIS requires dual antiplatelet therapy (DAPT) — typically aspirin plus clopidogrel — started 3–5 days before the procedure and continued for 3–6 months post-procedure, transitioning to single antiplatelet thereafter. This antiplatelet requirement distinguishes stent-assisted coiling with LVIS from purely intrasaccular approaches like WEB SL that generally do not require long-term DAPT.
What is the difference between LVIS™ and LVIS™ EVO?
LVIS EVO is a newer, lower-profile stent with even closer matched delivery and deployment diameters for improved navigability in tortuous anatomy. It covers nominal diameters 2.5–4.0 mm. Both LVIS and LVIS EVO use braided construction and full-length radiopacity; LVIS EVO is preferred when delivery forces must be minimized in technically challenging access routes.