CASPER™Код изделия (REF): CPR-0725-143RX
CASPER™ is a dual-layer carotid artery stent that addresses the most critical limitation of conventional single-layer carotid stents: the risk of embolic plaque debris release during and after deployment. CASPER pairs a standard outer nitinol stent scaffold — providing the radial force needed to stabilize the lesion and maintain vessel patency — with an inner micromesh layer of high-density nitinol. The inner mesh creates a fine-mesh liner inside the stent that acts as a physical barrier to plaque prolapse through the stent struts, reducing the rate of post-deployment debris release that has been associated with procedural stroke in carotid artery stenting. The dual-layer design gives CASPER a distinct advantage in patients with vulnerable, lipid-rich, or heavily calcified plaque where the risk of periprocedural embolization is highest — the same patients who are highest-risk candidates for carotid endarterectomy. Clinical data from the CRISTAL trial demonstrate that CASPER achieves low procedural stroke rates consistent with its embolic-protective mechanism. CASPER is available in diameters from 5 mm to 10 mm and dual-layer lengths from 16 mm to 40 mm, with a standard 0.014 in rapid-exchange delivery system. The overall implanted length is longer than the dual-layer segment to accommodate the transition zones at each end.
Эта страница содержит сведения о каталожном коде (REF) CPR-0725-143RX, одной из 17 доступных конфигураций CASPER™. См. полный обзор CASPER™ по каждой конфигурации.
Доступно под кодом(-ами) изделия CPR-0520-143RX, CPR-0530-143RX, CPR-0540-143RX, CPR-0616-143RX, CPR-0625-143RX, CPR-0630-143RX, CPR-0718-143RX, CPR-0725-143RX и ещё 9 (см. раздел «Информация для заказа» ниже).
Размеры и технические характеристики
- Diameter range
- 5 mm – 10 mm
- Dual layer length range
- 16 mm – 40 mm
- Delivery
- 0.014" rapid-exchange
Производитель: Terumo Neuro (MicroVention, Inc.) · Источник данных: terumoneuro.com
Идентификация и технические характеристики изделия
Референсные идентификаторы для закупок, регистрации и тендерной документации.
| Код изделия | CPR-0725-143RX |
|---|---|
| Номер(а) REF | CPR-0520-143RX, CPR-0530-143RX, CPR-0540-143RX, CPR-0616-143RX, CPR-0625-143RX, CPR-0630-143RX, CPR-0718-143RX, CPR-0725-143RX, CPR-0730-143RX, CPR-0820-143RX, CPR-0825-143RX, CPR-0830-143RX, CPR-0840-143RX, CPR-0920-143RX, CPR-0930-143RX, CPR-1020-143RX, CPR-1030-143RX |
| Производитель | Terumo Neuro (MicroVention, Inc.) |
| Бренд | Terumo Neuro (MicroVention) |
| Семейство продукции | Каротидные стенты |
| Доступность по странам | Азербайджан |
Клиническое применение
CASPER™ — это carotid artery stent в семействе Каротидные стенты от Terumo Neuro (MicroVention, Inc.), применяемый специалистами по интервенционным вмешательствам в процедурах, где показано использование carotid artery stent данного класса. Поставляется в 17 конфигурациях (каталожные коды с CPR-0520-143RX по CPR-1030-143RX) для соответствия анатомическим и процедурным требованиям.
Для получения полного перечня показаний к применению, противопоказаний и инструкции по применению (IFU) запросите официальную документацию Terumo Neuro (MicroVention) через нашу клиническую команду. Azmed Devices поставляет CASPER™ больницам и клиникам по всему Азербайджану.
Информация для заказа
Каталожные референсные коды согласно публикациям Terumo Neuro (MicroVention). Свяжитесь с нами для подтверждения текущей доступности.
| Catalog # | Diameter (mm) | Dual Layer Length (mm) | Implanted Overall Length (mm) |
|---|---|---|---|
| CPR-0520-143RX | 5 | 20 | 33 |
| CPR-0530-143RX | 5 | 30 | 47 |
| CPR-0540-143RX | 5 | 40 | 59 |
| CPR-0616-143RX | 6 | 16 | 32 |
| CPR-0625-143RX | 6 | 25 | 44 |
| CPR-0630-143RX | 6 | 30 | 53 |
| CPR-0718-143RX | 7 | 18 | 35 |
| CPR-0725-143RX | 7 | 25 | 47 |
| CPR-0730-143RX | 7 | 30 | 53 |
| CPR-0820-143RX | 8 | 20 | 36 |
| CPR-0825-143RX | 8 | 25 | 49 |
| CPR-0830-143RX | 8 | 30 | 55 |
| CPR-0840-143RX | 8 | 40 | 67 |
| CPR-0920-143RX | 9 | 20 | 45 |
| CPR-0930-143RX | 9 | 30 | 55 |
| CPR-1020-143RX | 10 | 20 | 45 |
| CPR-1030-143RX | 10 | 30 | 55 |
Загрузки и документация
Инструкция по применению (IFU), технические спецификации и клиническая литература для CASPER™ доступны по запросу у нашей клинической команды.
Запросить документациюЧасто задаваемые вопросы
- What is CASPER™ and why does it have a dual-layer design?
- CASPER™ is a dual-layer carotid artery stent designed to reduce embolic plaque debris release during and after carotid artery stenting. A standard nitinol outer stent provides the radial force to stabilize the plaque; an inner micromesh layer creates a fine-pore liner inside the stent that physically blocks plaque prolapse through the stent struts — the primary mechanism of periprocedural embolic stroke in conventional single-layer carotid stents.
- What sizes does CASPER™ come in?
- CASPER is available in diameters from 5 mm to 10 mm and dual-layer lengths from 16 mm to 40 mm. Catalog numbers run from CPR-0520-143RX (5 mm × 20 mm dual layer) through CPR-1030-143RX (10 mm × 30 mm). The overall implanted stent length is longer than the dual-layer segment to accommodate the transition zones.
- What delivery system does CASPER™ use?
- CASPER uses a standard 0.014 in rapid-exchange (RX) delivery system, compatible with conventional 6Fr guide catheter systems and standard 0.014 in coronary/peripheral guidewires. No dedicated delivery hardware is required beyond a standard carotid artery stenting setup.
- What clinical evidence exists for CASPER™?
- CASPER has been evaluated in the prospective CRISTAL trial (Carotid stenting with dual-layer mesh CArotiD stent versus bare metal stent for treatment of carotid artery stenosis). The trial demonstrated low rates of periprocedural ipsilateral stroke with CASPER, consistent with the embolic protection mechanism of the inner micromesh. Multiple single-centre series also report CASPER's performance in high-risk surgical patients including post-radiation and restenotic carotid disease.
- Does CASPER™ require antiplatelet therapy?
- Yes. CASPER requires dual antiplatelet therapy (aspirin + clopidogrel or ticagrelor) started at least 3–5 days before the procedure and continued for at least 4 weeks post-procedure, transitioning to single antiplatelet long-term — the same DAPT protocol as other carotid artery stents.